Monday, 27 August 2018

Pumps, Pumping principles and Significance

Hii Everyone.....!!! Back with a post about pumps. This is a general post which presents you detailing about principles of pumping, major components of pumps, their significance and how to efficiently enhance the pump life time and general troubleshooting issues those happen during pumping.

Hope many of you are aware of these topics, but this post has a chronology about pumping in details, and this is dedicated to one of my colleague Mr. Lalith Kumar Panwar.

What is a Pump ?
A pump is a  physical contrivance  that is used to deliver fluids from one location to other through conduits.

Principles of liquid pumping

Means of producing fluid flow: There are six basic means employed to cause the fluids to flow.
1.       Gravity
2.       Displacement
3.       Centrifugal force
4.       Electromagnetic force
5.       Transfer of momentum
6.       Mechanical impulse




Displacement: Discharge of a fluid from a vessel by partially or completely displacing it’s internal volume with a second fluid is the principle upon which these fluid transport devices operate.

Common features of these devices

1.       They are adaptable to high  pressure operation
2.       The flow rate through the pump is variable
3.       Mechanical considerations limit  max throughputs.
4.       The devices are capable of efficient performance at extremely low volume throughput         rates

Centrifugal Force :
Basic function of this pump is to produce kinetic energy by action of centrifugal force and then to convert this energy into pressure by efficiently reducing the velocity of the flowing fluid.

General characteristics of these devices.
1.       Discharge is relatively free of pulsation.
2.       Mech. Design lends itself to high throughputs.
3.       Devices are capable of efficient performance over a wide range of pressures and                  capacities even at constant speed operations.
4.       Discharge pressure is a function of fluid density.
5.       These are relatively small high speed devices and less costly.





Electromagnetic Force:
When the fluid is an electrical conductor, as is the case with molten metals, an electromagnetic field is impressed around the fluid conduit in such a way that a driving force is created that will cause the flow.

Such pumps are used in handling of heat transfer liquids for nuclear reactors.

Transfer Of Momentum:
Deceleration of one fluid inorder to transfer it’s momentum to a second fluid is the principle commonly used in handling corrosive materials, in pumping from inaccessible depths, or for evacuation. Eg. jets & educators.

Measurement Of Performance

Performance of a pump is measured in terms of work done which is the product of mass rate of the fluid flow and the total differential pressure measured immediately before and after the device. This differential pressure is usually expressed in the height of column of fluid equivalent under adiabatic conditions.

Work done = capacity x head





Total Dynamic Head
Difference between total discharge head and total suction head.

Total Suction Head: This is the guage pressure reading at the suction port + atm pressure + the velocity head at the point of guage attachment.

Before installation of pump suction head is evaluated as

                hs = hss – hfs
hss- static suction head
hfs- suction friction head.

Static Suction Head : This is the vertical distance measured from the free surface of the liquid source to the pump centreline + the absolute pressure at the liquid surface.

Total Discharge head: This is the reading of the guage at the discharge flange of the pump + the barometer reading + the velocity head at the point of attachment of the guage.

Before installation of pump discharge head is evaluated as
                hd = hsd + hfd
hsd- static discharge head
hfd- discharge friction head

Static Discharge Head : This is the vertical distance measured from the free surface of the liquid in the receiver to the pump centreline + the absolute pressure at the liquid surface.

Total static head is the difference between discharge & suction static heads.




Velocity Head:

                hv = v²/2g

Friction Head : This is the pressure required to overcome the resistance to flow in pipes and fittings.
Frictional loss is the drop in the pressure due to friction. This is mainly due to fittings such as expansions, contractions, valves, elbows used in piping systems. Also factors such as shaft work and velocity or elevation change influence the pressure drop.

Work  Performed in Pumping

Regardless of the service of the pump, all energy imparted to liquid in performing the service must be accounted for.
Thus the Power Output of the pump  ought to be calculated.

Power Poutput is the product of total dynamic head and the mass of the liquid pumped in given time.

Power output in Kilowatts = HQr/3.670x105
H= total dynamic head expressed in Nm/kg
Q= capacity in m3/h
r= liquid density in kg/m3

The power input to a pump is greater than the power output because of internal losses resulting from friction, leakage etc. The effeciency of pump therefore is
                h = power output/ power input



Net Positive Suction Head

There are some limitations of  a pump suction. Whenever the pressure in a liquid drops below the vapor pressure corresponding to it’s temperature, the liquid will vaporise.
When this happens within an operating pump, the vapor bubbles will be carried along to a point of higher pressure where they suddenly collapse. This phenomenon is called Cavitation.


For the desired capacity NPSHA should always be equal to or greater than NPSHR.
NPSHA can be calculated as
                NPSHA = hss-hfs-po
                                = static suction head – suction friction head – vapor pressure
For an existing installation,
                NPSHA = atm + hgs – po + hvs
                hgs = suction guage reading
                hvs = velocity head at the point of guage attachment
                po   = vapor pressure

NPSHR depends on the characteristics of the liquid, the total head, the pump speed, the capacity and impeller design.


Pump Selection

For selection of a pump for any service, it is necessary to know the liquid to be handled, the total dynamic head, the suction and discharge heads, and in most cases, temp, viscosity, vap pressure and specific gravity. Presence of solids in liquid call for special material of construction. Solids may accelerate  erosion and corrosion, have a tendency to agglomerate or require delicate handling to prevent undesirable degradation. In such cases a recessed impeller centrifugal pump can be used.



Centrifugal Pump

It is a device which combines the use of centrifugal force with mechanical impulse to produce an increase in pressure.

Primary Advantages

Simplicity, low cost, uniform flow, small floor space, low maintenance expense, quiet operation and adaptability for use with a motor or a turbine drive.

Construction of Centrifugal Pump

In it’s simplest for a centrifugal pump consists of an impeller rotating in a case.
The liquid is forced, by atm or other pressure, into a set of rotating vanes. These vanes constitute an impeller which discharges the liquid at it’s periphery at a higher velocity. This velocity is converted to pressure energy by means of a volute or by set of stationary diffusion vanes surrounding the impeller periphery.

Impellers are classified as
1.       Radial flow impellers
2.       Axial flow impellers
3.       Mixed flow impellers
Based on the direction of flow in reference to the axis of rotation.

They are further classified as
1.  Single suction with single inlet on one side
2. Double suction with fluid flowing to the impeller symmetrically from both sides.



Mechanical construction of impellers gives a still further sub division.
1.  Enclosed or shrouded – shrouds or side walls enclosing the fluid ways
2. Open with no shrouds
3. Semi-open

Casings are of three types
1.   Circular – it is an annular chamber around the impeller. No attempt is made to overcome the losses arising from eddies and shock when the liquid leaving the impeller at relatively high velocities enters this chamber.
2.   Volute casing – it takes the form of a spiral increasing uniformly in cross sectional area as the outlet is approached. The volute efficiently converts kinetic (velocity) energy imparted to the liquid by the impeller into pressure energy.
3.   Diffuser type – guide vanes or diffusers are interposed between the impeller discharge and the casing chamber. Losses are kept to minimum 7 efficiency is improved to a wider range of capacities.

Centrifugal Pump Action

Power from outside source is applied to shaft, rotating the impeller within the stationary casing. The blades of impeller while revolving produce a reduction in pressure at the entrance or eye of the impeller. This causes the liquid to flow into the impeller from the suction pipe. This liquid is forced outward along the blades at increasing tangential velocity. The velocity head it has acquired when it leaves the blade tips is changed to pressure head as the liquid passes into the volute chamber and thence out the discharge .

Centrifugal Pump Characteristics

The head produced by the pump will be same for any liquid of same viscosity. The pressure rise will however vary in proportion to the specific gravity.

Similarity relationship/ Affinity Laws
1.       Q is proportional to impeller rotational speed, N
2.       Head varies as square of the impeller rotational speed.
3.       Break horsepower (BHP) varies as the cube of the impeller rotational speed.

The affinity laws are
                                Constant impeller diameter               constant impeller speed
Capacity                               Q1/Q2 = N1/N2                                    Q1/Q2 = D1/D2
Head                                  H1/H2 = N1²/N2²                                h1/h2 = D1²/D2²
BHP                            BHP1/BHP2=N13/N23                        BHP1/BHP2=P13/P23


Centrifugal Pump Selection

The specific speed of the pump plays a major role in selecting a pump for particular opplication.

                Ns = NQ0.5/H0.75

N is in rpm
Q is in gpm
H is in ft.lbf/lbm

Specific speed is a parameter that defines the speed at which impellers of geometrically similar design have to be run to discharge one gallon per minute against one foot head.
Thus pumps with a low specific speeds have low capacities & vice versa.

Another parameter that helps in evaluating the pump suction limitations such as cavitation is suction specific speed

                S = NQ1/2 / (NPSH)3/4

Centrifugal Pump Trouble Shooting

Hydraulic performance & diagnostics

The most significant problems caused by hydraulic dynamic forces are

1.   Cavitation:

Causes And Effect: Cavitation is the formation of vapor bubbles in any flow that is subjected to an ambient pressure equal to or less than the vapor pressure of the liquid being pumped. Cavitation damage is loss of metal produced by the collapse of the vapor bubbles against the metal surfaces of the impeller or casing.

Diagnosis from Pump Operation: Pump operation in presence of cavitation will reduce both the total head & output capacity. A steady crackling noise in and around the pump suction indicates cavitation. Cavitation damage from inadequate NPSH occurs on low pressure or the visible surface of the impeller inlet vane.

Instrumentation: A suction guage or manometer in the pump suction can be used to determine whether NPSH available is equal to or greater than NPSHR

      Corrective Procedure: If additional NPSH cannot be supplied, then the capacity of the            pump should be reduced to the point where NPSHR is equal to or less than the NPSHA.          If this is not possible than a small amount of air can be bled into the pump suction to              reduce the damage associated with cavitation.




2.   Suction & Discharge Recirculation

Cause & Effect: Recirculation occurs at reduced flows and is the reversal of  a portion of the flow back through the impeller. Recirculation at the impeller inlet is suction recirculation & that at outlet is diacharge recirculation. These can be very damaging to pump operation & should be avoided in continuous opertation.

Diagnosis: Suction recirculation will rpoduce a loud crackling noise in and around the pump suction. This is a random crackling noise with high-intensity knocks. Discharge recirculation produces highest intensity knocks in the discharge volute or diffuser.

Instrumentation: This can be determined by monitoring pressure pulsations in suction & discharge casings.

Corrective Procedure :
  1. Increase the output capacity of the pump.
  2. Install a bypass between suction and discharge of pump
  3. Bleed air into suction to reduce noise & vibration
  4. Substitute a harder material for impeller to reduce the damage. 




Minimum flow control :

Sources of trouble at reduced flow :

1.   Thermal : The unavoidable energy conversion loss in pump warms the liquid
2.   Hydraulic : When flow decreases far enough the impeller encounters suction or discharge re-circulation or perhaps both. Flashing, cavitation and shock occur often with vibration and serious Damage.

3.   Mechanical : Both constant and fluctuating loads in radial and axial directions increase as the pump capacity falls causing bearing damage, shaft and impeller breakage, rubbing wear on Casing.
4.   Abrasive wear : Liquids containing large amount of abrasive particles such as sand or ash must flow continuously  through the pump. If flow decreases particles can circulate inside the pump passages and quickly erode the impeller and casing.




Methods of Protection :
1.       Pump motor shut off at predetermined discharge head.
2.       Pump motor shut off at predetermined temperature.
3.       Pump motor shut off at predetermined capacity

4.       Providing a bypass.     

That's it.......!!!!

This is what i know about pumps, if anyone wanna add something here to this, pl comment or contact me through the contact me page available at top.

Any queries feel free to comment.......!!

Comments are most appreciated.......!!!!

Below are the references, which i've considered for posting:
1. Pump Hydraulics, Sizing and selection, KLM Technology and group,
2. Design and Flow Analysis of Double-suction Centrifugal Pump Impeller, by NWE NI WIN. 

Related Posts:
[How to] Design a Scrubber ? 
Calculate moisture absorbents quantty require for API Packing  
Chemical solvent properties  

[How to] Calculate NPSH (Net Positive Suction Head) ?


About The Author


Hi! I am Ajay Kumar Kalva, Currently serving as the CEO of this site, a tech geek by passion, and a chemical process engineer by profession, i'm interested in writing articles regarding technology, hacking and pharma technology.
Follow Me on Twitter AjaySpectator & Computer Innovations


Thursday, 9 August 2018

[How to] Evaluate filtration feasibility in ANFD


Hiii all......!!!

Its been a gap, since i been posting regularly, 



Recently i've received a query about one of my previous post i.e., about filtration, i've posted about selection of filters, and one guy from a reputed pharma has approached me through mail, as he need in depth about ANFD filtration, and i thought that it can make a separate post as many of us were not upto the mark in this topic, as many a time we cant distinguish which sort of reaction mass can be filtered in ANFD.

For distinguishing the same, we should be possessing enough knowledge about filtration terminology and the commonly used parameters for explaining the filtration.

So, lets startup with some technical terms,





What is Permeation ?

Permeation is type of passage through a resistive medium.




What is Permeative flux ?

Usually flux is defined as amount / quantity of material passing through an area in specified time. Coming to Permeative flux, it can be defined as amout / quantity that is permeated through a material medium of unti area in specified time. 
Usually given units as Liters/min.Sq.m.

What is Specific Cake resistance ?

During filtering slurries, cake will be formed on the filtration barrier, and as on filtration going the cake thickness will increase depending upon the retained volume. The retained cake will add some excess resistance to the slurry which is being filtered along with the filter. The excess added resistance is Specific cake resistance. will hold units as m / Kg.




What is cake Concentration ?

Cake concentration in terms of filtration denotes the solids concentration in slurry. 
will have units like density i.e., Kg/Cu.m.



The above mentioned are the most used terms to describe / distinguish the nature of filtration.

Now lets jump into the topic and based on the preliminary evaluation we can conclude whether the reaction mass can be filtered or not, out of those i can mention some here, 




If reaction mass is Sticky / slimy / free flowing ANFD is not preferred,
If the material nature is Crystalline, ANFD is preferred,
If the reaction mass is acidic in nature, ANFD can be preferred, if its basic then the mass would be sticky, so ANFD is not preferred,
If the nucleation is better i.e., coarser, ANFD is preferred, if its finer ANFD is not preferred.

That's it..!!! This is preliminary evaluation, if i've missed out something just go ahead and comment, i'll add those in the above listing.

Sometimes we cant decide whether we need to select an ANFD or not, and at that time we need to consider a experiment with a buckner filter and performing an experiment is an easy task, but evaluating that and generating a systematic data is vital.


You may also like:
[How to] Reduce drying time in ANFD effectively ? 
[How To] Calculate assay of liquid product without concentration ?  

So, now lemme tell you what sort of input need to be recorded from the performed experiment,

1. Pore Size of the filter cloth,
2. Filter Dia,
3. Reaction mass volume,
4. Applied vacuum,
5. Filtrate volume,
6. Filtration time,
7. Weight of wet cake,
8. Cake height.

So, in a total the above 8 parameters need to recorded perfectly, so in case of any miss recording / wrong recording, it may lead to faltu results.




So now, Lets start the calculation,

Permeation flux = Filtrate volume / ( Filter area x Filtration duration ),

Filter Area = 0.785 x ( Filter Dia ^ 2 ),

Cake Concentration = ( Wet cake wt.  x 0.2 / Reaction mass volume ) x 1000,


                                                 ( 2 x (Filter Area^2) x 133.32 x Filtration time x applied vacuum) 
Specific Cake Resistance = ____________________________________________
                                                 ( Cake Concentration x Rxn. mass viscosity x (Rxn. mass vol.^2))


Its all done now .....!!!

Now lets know about the limits of the above discussed to distinguish the filtration,


If the permeation flux is greater than 45 Lts / mins. Sq.m, then it would be good filtration and you can go ahead with ANFD,
If it is between 15 and 45, it would be moderate filtration and while scaling up we cant assure that the filtration will be good enough and even we cant assure consistent filtration rate, so we have to prefer an trial in pilot plant,
If the rate below 15, its better to move with centrifuge or filter press.





Like Permeation flux we are also having Specific cake resistance, below is the classification to distinguish the filtration nature,

If cake resistance is ,

10 ^ 7 to 10^8           -        Good filtration,
10^8  to  10^10         -        Moderate filtration,
above 10^10              -        Slow filtration


That's it.......!! This post is done here itself,


Lets suppose, now here i'll give one case study / sample calculation with some input data,

Filter cloth size      :  5 ยต,

Buckner filter dia  :  5 cms,

Slurry volume        :  1000 ml,

Viscosity                 :  0.3 cP,

Applied Vacuum  : 500 mmHg,

Filtrate volume    :  650 ml,

Filtration time     :   20 minutes,

Wet cake weight :  230 grams,

Cake thickness   :   150 mm,


Also Read:
[How to] Evaluate RC1e study ? 
[How To] Select a batch size for a manufacturing process ?  

Now the result is,




Permeation flux - 16.56 Lt/Sq.m. min,

Cake concentration - 46.00 Kg/Cu.m,

Specific cake resistance  -  4.46 x 10^10 m/Kg.

So as per the above discussion, the filtration is poor, not good enough in ANFD.

I've prepared an automated sheet for you guys and this sheet will do the work for you,

Below is the screenshot of the automated sheet:


Credits: Pharma Engineering






Any queries feel free to comment / reach me through mail ....!!!

Comments are most appreciated ......!!!



Related Posts:
[How to] Design a Scrubber ? 
Guidelines for Process Development & Optimization  
[How to] Select a filter for a specific operation ?  
[How to] Calculate NPSH (Net Positive Suction Head) ?

About The Author


Hi! I am Ajay Kumar Kalva, Currently serving as the CEO of this site, a tech geek by passion, and a chemical process engineer by profession, i'm interested in writing articles regarding technology, hacking and pharma technology.
Follow Me on Twitter AjaySpectator & Computer Innovations